SELDI

SCINTI-ELECTRONIC DETECTORS

SELDI Module Detectors      SELDI Type Detectors 

SELDI Detector

 • Single and multichannel

 • Module concept

 • CWO & CsI(Tl) based SELDI

 • Radiation sensitivity:  30 (CWO), 90 (CsI(Tl)) nA·min·R-1·cm-2

 • 11 modifications

NEW DESIGN: High sensitive spectrometric SELDI detector on the base on new light collection system and module concept

 Seldi is a series of scinti-electronic radiation detectors on the basis of "scintillator - photodiode" assembly.

 At present a concept of a module-type detection block has been developed. Such block is mounted of individual modules with a specified energy resolution. Each module is designed so that to provide a maximum light yield and energy resolution. The number of modules is defined proceeding from the required sensitivity of the block as a whole. The block is positioned in a common housing with a common scheme of signal processing from all the modules.

 The module-type block allows to determine the direction to the radiation source while not displacing the block. The ratio "signal-noise" has been improved.

 The base detection blocks with the crystal volume from 8 to 64 and energy resolution by 137Cs from 5.5 to 14% have been developed.

 The consumption power for one module - 60 mWt.

137Cs spectrum for SELDI-1

60Co spectrum for SELDI-1

241Am spectrum for SELDI-1

SELDI Module Detectors  

Parameter

 SELDI-1

 SELDI-2

Energy range, MeV

9

1

Sensitivity, pulse/s/mkR/h

on 137Cs

on 60Cs

on 241Am

 

> 11

> 9

> 6

 

> 4.5

> 3.0

> 1.5

Energy resolution on 137Cs, %

7.5-8.5

7.5

The ratio peak/valley by 60Co not less than

10

10

Output pulse parameters

 - pulse height, mV/keV

 - duration on 0.5 pulse height, mks

 

0.8

12.5

 

0.8

50

In-set temperature sensor, mV/°C

2

2

Supply voltage, V

±9

±9

Consumed current, mA

14

5

Crystal size, mm

44x44x52

22x22x52

Detector size, mm

dia.64x112

dia.35x100

SELDI Type Detectors  

Type & nomenclature Dimensions, nm  Radiation sensivity, nAminR-1cm-2 Energy range, meV Input window area, mm Channels number, step Overall dimension, mm Intended applications

 SELDI-M.01

 SELDI-M.02

CdWO4,

CsI(Tl) 16x(4x4x1.4)

30

90

0.03-0.5 (X-rays) 4x1.4 16(1.57) 25.4x20x15 Inspection control

 SELDI.126-01

SELDI.126-02

CdWO4 2x(20x1.4x4) 2x(20x1.4x8)

30

0.15-10 (gamma)

4x1.4

8x1.4

2(1.7) 5x8x35 Tomography

 SELDI.127A

SELDI.127B

CdWO4,

CsI(Tl) 16x(4x12x1.4)

30

90

0.03-0.2 (X-rays) 2x1.4 16(1.57) 25.4x26x10 Defectoscopy
 SELDI.128-01

 CsI(Tl)

10x10x10

10-5R/h 0.05-3 10x10 1 19.5x29.5x20 Dosimetry
 SELDI.129

CdWO4

10x10x10

30 0.01-10 (gamma)

10x10

dia.11

1 dia.23x25 Dosimetry
 SELDI-M.03

 CsI(Tl) 16x(4x4x1.4)

90±10% 0.03-0.2 (X-rays) 4x1.5 16(1.57) 25.4x20x15 Inspection control
 SELDI-M.05

 CsI(Tl) 32x(4x4x0.7)

90 0.03-0.5 (X-rays) 4x0.7 32(0.78) 25.4x35x15 Introscopy
 SELDI-M.08

 CsI(Tl) 32x(4x4x0.7)

90±10% 0.05-3 (X-rays) 9x10 1 17x17x11 Introscopy
 SELDI.131A02

 CsI(Tl) 32x(4x4x0.7)

90±10% 0.01-0.05 (X-rays) 4x1.2 16(1.6) 25.4x20x5 Introscopy

Copyright © 1998-2000, Amcrys-H. All rights reserved.

60, Lenin Ave, Kharkov  310001, Ukraine
Tel. 380(572)307906   Fax 380(572)321082.